From b28f97f3526859633fde603764b827389279d10f Mon Sep 17 00:00:00 2001 From: Denis Chevalier Date: Mon, 10 Aug 2026 22:32:38 +0200 Subject: extract figures in separate files --- tables/power-distribution-board-functions.typ | 24 ++++++++++++++++++++++++ 1 file changed, 24 insertions(+) create mode 100644 tables/power-distribution-board-functions.typ (limited to 'tables/power-distribution-board-functions.typ') diff --git a/tables/power-distribution-board-functions.typ b/tables/power-distribution-board-functions.typ new file mode 100644 index 0000000..b1991e4 --- /dev/null +++ b/tables/power-distribution-board-functions.typ @@ -0,0 +1,24 @@ +#import "../lib/unify.typ": qty + +#figure( + table( + columns: 2, + table.header([Function], [Requirement]), + [AC-DC conversion], + [Mains input to $plus.minus qty(15, "V")$, $plus.minus qty(5, "VD")$ rails. Can be external or internal], + + [Reference generation], [$plus.minus qty(10.0000, "V")$ precision references], + + [Master oscillator generation], [Generation of the $qty(10, "MHz")$ sine wave reference], + + [Distribution], + [ + - One female DB-25 connector per module position, + - One female isolated BNC connector per module position + ], + + [Calibration], [Front-panel accessible switches], + [Protection], [Overcurrent, overvoltage, thermal shutdown], + ), + caption: [Power distribution board functional requirements], +) -- cgit