#import "../lib/unify.typ": qty
#figure(
table(
columns: 2,
table.header([Parameter], [Requirement]),
[Isolation voltage], [$gt.eq qty(3000, "VAC")$ mains to SELV],
[Creepage / Clearance], [Per IEC 60950-1 or IEC 62368-1],
[Fusing], [Primary slide, appropriately rated],
[Earth bonding], [Continuous, $lt qty(0.1, "ohm")$ to mains earth],
),
caption: [Mains isolation requirements],
) <table-chassis-mains-isolation>
|